A used tote can legally carry regulated cargo. The plate has to say so.
Regulated liquids need a container with a valid design-type marking and a current periodic test. That is a paperwork and testing problem, not a reason to buy new. We inspect, leakproofness test, re-mark and record in house, which keeps thousands of perfectly serviceable UN-rated containers in regulated service instead of in a scrap bale.

Short answer
- Design type
- 31HA1 / Y
- Test interval
- 2.5 yr
- Periodic
- 5 yr
- Records
- Same day
Book recertification.
Give us the count and, if you can, a photograph of one plate. Design type and manufacture date determine what testing is due and what it will cost.
Reading a design-type marking.
Every rated IBC carries a code that records what it is, what it may carry and when it was made. Learn to read it and you can assess a container in ten seconds.
| Segment | Means | Why it matters |
|---|---|---|
| 31 | IBC for liquids, filled or discharged under gravity or pressure | Confirms it is a liquid-rated IBC, not a solids IBC (11) |
| HA1 | Composite: rigid plastic inner with outer metal frame | Identifies construction; HZ2 and 31A differ materially |
| Y | Packing group II and III cargo | X covers I, II and III; Z covers III only |
| 03 26 | Month and year of manufacture | Drives the 5-year periodic clock |
| USA | Country of design-type approval | Where the approval was issued |
| M1234 | Manufacturer or approval reference | Traces the approval holder |
From arrival to marked and released.
- 01
Identify
Plate photographed and transcribed, design type and manufacture date recorded, previous test dates established from markings and paperwork.
Step 01 - 02
Inspect
External and internal inspection: cage integrity, welds, feet, deck, receptacle wall, crazing, closures, gasket seats and outlet condition.
Step 02 - 03
Test
Sealed and pressurised to the required leakproofness test pressure and held while closures, seams and the outlet are checked for decay and leakage.
Step 03 - 04
Mark & record
Passed containers are marked with the test date and released with a written record against the serial number. Failures are reported unit by unit with the reason.
Step 04
Why units do not pass
- Illegible, painted over or missing design-type plate
- Crazing or stress whitening in the receptacle wall
- Cracked or previously repaired welds in load-bearing cage members
- Deformed outlet boss causing seal decay under test
- Deck or foot damage that compromises the base assembly
- Repairs or modifications that alter the approved design type
How to keep a fleet certified
- Record the plate date at purchase, not at the first audit
- Test on a calendar, batching units so a truck is never idle
- Never paint, label over or pressure-blast a marking plate
- Replace gaskets and valves proactively — see parts
- Combine testing with a wash run so units move once
- Or hand the whole problem to a managed programme
Recertification, answered.
01How often does an IBC need retesting?
02Can any used tote be recertified?
03What does the leakproofness test involve?
04Does rebottling reset the design type?
05Who keeps the records?
Regulatory intervals and requirements summarised here are provided for general guidance. Always verify against the current applicable regulation for your jurisdiction, mode of transport and specific cargo before shipping.
Reading a design-type plate character by character.
The plate is the container's legal identity. Learn the segments and you can assess regulatory status in about ten seconds.
| Code | Meaning | Where you see it |
|---|---|---|
| 11 | IBC for solids, gravity filled or discharged | Bulk powder and granule containers |
| 13 | IBC for solids, filled or discharged under pressure | Pneumatic transfer units |
| 21 | IBC for solids under pressure | Specialist solids handling |
| 31 | IBC for liquids | Every liquid tote on this site |
| Code | Construction | Example | Repair implication |
|---|---|---|---|
| A | Steel | 31A — all-metal IBC | Weld repair by a competent welder |
| B | Aluminium | 31B | Uncommon in general industry |
| H | Rigid plastic | 31H1 — plastic IBC with structural equipment | Limited repair options |
| HA1 | Composite: rigid plastic inner, steel outer | 31HA1 — the standard tote | Cage repair routine; bottle replaceable |
| HZ2 | Composite: flexible inner, outer casing | 31HZ2 | Less common |
| N | Metal other than steel or aluminium | 31N | Rare |
| Segment | Example | Meaning | Why it matters |
|---|---|---|---|
| Packing group | Y | Approved for PG II and III | X covers I–III; Z covers III only |
| Date | 0326 | March 2026 | Starts the five-year periodic clock |
| Country | USA | State issuing the design-type approval | Which authority stands behind it |
| Manufacturer ref | M1234 | Approval holder code | Traceability |
| Maximum gross mass | 1135 kg | Weight limit when filled | Not a volume limit |
| Stacking test load | 2500 kg | What the design carried when stacked | Governs stacking in service |
| Test pressure | 100 kPa | Where the design is pressure rated | Applies to pressure discharge |
| Last periodic test | Separate stamp | Whether the container is in test | The plate alone is not enough |
Batching testing instead of discovering it.
Testing fifteen containers on one visit costs a fraction of testing one container fifteen times. Without a schedule, the second pattern is what happens.
| Manufacture date | Units | 2.5-year check | 5-year periodic | Action this quarter |
|---|---|---|---|---|
| 2021 Q3 | 18 | Overdue | Due now | Batch test |
| 2022 Q1 | 24 | Current | 2027 Q1 | Schedule |
| 2022 Q4 | 11 | Current | 2027 Q4 | Schedule |
| 2023 Q2 | 31 | Due next quarter | 2028 Q2 | Book with the next wash run |
| 2019 Q2 | 6 | Overdue | Overdue | Test or move to non-regulated service |
| Illegible plate | 3 | N/A | N/A | Non-regulated service only |
Why units do not pass, and what happens to them.
| Reason | Recoverable? | Route | Prevention |
|---|---|---|---|
| Illegible or missing plate | No | Non-regulated service or reclaim | Never paint, label over or blast a plate |
| Crazing in the receptacle wall | No | Rebottling | Match chemistry to the container |
| Stress whitening | No | Rebottling | Do not overload or overstack |
| Cracked weld in a load-bearing member | Usually | Cage shop, then retest | Careful handling |
| Deformed outlet boss | Sometimes | Refit and retest | Do not force adapters |
| Base or foot damage | Usually | Cage shop, then retest | Level standing, correct lifts |
| Repair departing from the design type | No | Non-regulated service | Restore to type, do not modify |
| Pressure decay after gasket replacement | No | Rebottling or reclaim | — |
Intervals and requirements summarised on this page are general guidance. Verify against the current regulation applicable to your jurisdiction, transport mode and cargo before shipping regulated material.
More questions, answered
01How often does a rated container need retesting?
02Can any used container be recertified?
03What does the leakproofness test involve?
04Does age alone disqualify a container?
05Can a marking plate be replaced?
06Who keeps the test records?
07Can testing be combined with a wash run?
Photograph one plate. Send it to us.
Design type and date are all we need to tell you what testing is due across the fleet and what it will cost.