Skip to content
IBC Recycling ServicesGet a quote
Service · Compliance

A used tote can legally carry regulated cargo. The plate has to say so.

Regulated liquids need a container with a valid design-type marking and a current periodic test. That is a paperwork and testing problem, not a reason to buy new. We inspect, leakproofness test, re-mark and record in house, which keeps thousands of perfectly serviceable UN-rated containers in regulated service instead of in a scrap bale.

An IBC tote showing its metal design-type marking plate on the cage
Fig. 01The plate on the side is the container's legal identity. Protect it.

Short answer

Leakproofness test and external inspection at intervals not exceeding 2.5 years, full periodic inspection at 5 years. We test, mark and issue records in house.
Design type
31HA1 / Y
Test interval
2.5 yr
Periodic
5 yr
Records
Same day
Form 01 · Spec request

Book recertification.

Give us the count and, if you can, a photograph of one plate. Design type and manufacture date determine what testing is due and what it will cost.

Letters only

Letters only

A working inbox — we reply here

US or Canada · 10 digits · (216) 987-6543

US state or Canadian province

US ZIP 44135 · Canada M5V 2T6

Whole number · totes, cages or loads

No phone number needed to reach us — we quote by email, usually within one business day. Your details are used only to price and schedule your totes.

What the plate means

Reading a design-type marking.

Every rated IBC carries a code that records what it is, what it may carry and when it was made. Learn to read it and you can assess a container in ten seconds.

Decoding 31HA1 / Y / 03 26 / USA / M1234
SegmentMeansWhy it matters
31IBC for liquids, filled or discharged under gravity or pressureConfirms it is a liquid-rated IBC, not a solids IBC (11)
HA1Composite: rigid plastic inner with outer metal frameIdentifies construction; HZ2 and 31A differ materially
YPacking group II and III cargoX covers I, II and III; Z covers III only
03 26Month and year of manufactureDrives the 5-year periodic clock
USACountry of design-type approvalWhere the approval was issued
M1234Manufacturer or approval referenceTraces the approval holder
The process

From arrival to marked and released.

  1. 01

    Identify

    Plate photographed and transcribed, design type and manufacture date recorded, previous test dates established from markings and paperwork.

    Step 01
  2. 02

    Inspect

    External and internal inspection: cage integrity, welds, feet, deck, receptacle wall, crazing, closures, gasket seats and outlet condition.

    Step 02
  3. 03

    Test

    Sealed and pressurised to the required leakproofness test pressure and held while closures, seams and the outlet are checked for decay and leakage.

    Step 03
  4. 04

    Mark & record

    Passed containers are marked with the test date and released with a written record against the serial number. Failures are reported unit by unit with the reason.

    Step 04
Common failures

Why units do not pass

  • Illegible, painted over or missing design-type plate
  • Crazing or stress whitening in the receptacle wall
  • Cracked or previously repaired welds in load-bearing cage members
  • Deformed outlet boss causing seal decay under test
  • Deck or foot damage that compromises the base assembly
  • Repairs or modifications that alter the approved design type
Practical advice

How to keep a fleet certified

  • Record the plate date at purchase, not at the first audit
  • Test on a calendar, batching units so a truck is never idle
  • Never paint, label over or pressure-blast a marking plate
  • Replace gaskets and valves proactively — see parts
  • Combine testing with a wash run so units move once
  • Or hand the whole problem to a managed programme
Questions

Recertification, answered.

01How often does an IBC need retesting?
Under US and international rules a composite IBC used for regulated liquids requires a leakproofness test and external inspection at intervals not exceeding two and a half years, and a full periodic inspection including that test at intervals not exceeding five years from the date of manufacture and from each subsequent periodic test. Always confirm against the current regulation text for your jurisdiction and cargo.
02Can any used tote be recertified?
No. The container must have a legible design-type marking, an intact and undamaged inner receptacle, a structurally sound cage and no repairs that alter the design type. A tote with an illegible plate cannot be recertified — it can only be sold for non-regulated service or reclaimed.
03What does the leakproofness test involve?
The container is sealed, pressurised with air to the required test pressure, and held while it is checked for decay and for leakage at the closures and outlet. Pass or fail is recorded against the serial number, and a passed unit is marked with the test date.
04Does rebottling reset the design type?
Fitting a replacement inner receptacle from an approved design-type family and re-marking accordingly is a recognised route back to rated service, provided the assembly matches the approval. We do this in house and issue the records with the container.
05Who keeps the records?
We keep ours and you get yours. Test records travel with the container and are reissued on request, because the inspector who eventually asks for them will ask you, not us.

Regulatory intervals and requirements summarised here are provided for general guidance. Always verify against the current applicable regulation for your jurisdiction, mode of transport and specific cargo before shipping.

Marking reference

Reading a design-type plate character by character.

The plate is the container's legal identity. Learn the segments and you can assess regulatory status in about ten seconds.

Container type codes — first two characters
CodeMeaningWhere you see it
11IBC for solids, gravity filled or dischargedBulk powder and granule containers
13IBC for solids, filled or discharged under pressurePneumatic transfer units
21IBC for solids under pressureSpecialist solids handling
31IBC for liquidsEvery liquid tote on this site
Construction codes
CodeConstructionExampleRepair implication
ASteel31A — all-metal IBCWeld repair by a competent welder
BAluminium31BUncommon in general industry
HRigid plastic31H1 — plastic IBC with structural equipmentLimited repair options
HA1Composite: rigid plastic inner, steel outer31HA1 — the standard toteCage repair routine; bottle replaceable
HZ2Composite: flexible inner, outer casing31HZ2Less common
NMetal other than steel or aluminium31NRare
Packing group letters and everything after
SegmentExampleMeaningWhy it matters
Packing groupYApproved for PG II and IIIX covers I–III; Z covers III only
Date0326March 2026Starts the five-year periodic clock
CountryUSAState issuing the design-type approvalWhich authority stands behind it
Manufacturer refM1234Approval holder codeTraceability
Maximum gross mass1135 kgWeight limit when filledNot a volume limit
Stacking test load2500 kgWhat the design carried when stackedGoverns stacking in service
Test pressure100 kPaWhere the design is pressure ratedApplies to pressure discharge
Last periodic testSeparate stampWhether the container is in testThe plate alone is not enough
Fleet scheduling

Batching testing instead of discovering it.

Testing fifteen containers on one visit costs a fraction of testing one container fifteen times. Without a schedule, the second pattern is what happens.

What a fleet certification schedule looks like
Manufacture dateUnits2.5-year check5-year periodicAction this quarter
2021 Q318OverdueDue nowBatch test
2022 Q124Current2027 Q1Schedule
2022 Q411Current2027 Q4Schedule
2023 Q231Due next quarter2028 Q2Book with the next wash run
2019 Q26OverdueOverdueTest or move to non-regulated service
Illegible plate3N/AN/ANon-regulated service only
Failure modes

Why units do not pass, and what happens to them.

Rejection reasons at the certification bench
ReasonRecoverable?RoutePrevention
Illegible or missing plateNoNon-regulated service or reclaimNever paint, label over or blast a plate
Crazing in the receptacle wallNoRebottlingMatch chemistry to the container
Stress whiteningNoRebottlingDo not overload or overstack
Cracked weld in a load-bearing memberUsuallyCage shop, then retestCareful handling
Deformed outlet bossSometimesRefit and retestDo not force adapters
Base or foot damageUsuallyCage shop, then retestLevel standing, correct lifts
Repair departing from the design typeNoNon-regulated serviceRestore to type, do not modify
Pressure decay after gasket replacementNoRebottling or reclaim—

Intervals and requirements summarised on this page are general guidance. Verify against the current regulation applicable to your jurisdiction, transport mode and cargo before shipping regulated material.

Extended FAQ · 7 questions

More questions, answered

01How often does a rated container need retesting?
Generally a leakproofness test with external inspection at intervals not exceeding two and a half years, and a full periodic inspection including that test at intervals not exceeding five years from manufacture and from each subsequent inspection. Verify against the regulation applicable to your jurisdiction and cargo.
02Can any used container be recertified?
No. It needs a legible design-type marking, an intact undamaged inner receptacle, a structurally sound cage and no repairs that alter the design type. A container with an illegible plate cannot be recertified at all.
03What does the leakproofness test involve?
The container is sealed, pressurised with air to the required test pressure and held while closures, seams and the outlet are checked for decay and leakage. Pass or fail is recorded against the serial, and a passed unit is marked with the test date.
04Does age alone disqualify a container?
No. There is a testing schedule, not an expiry date. We routinely recertify containers over a decade old, provided they have been kept in test and remain structurally sound.
05Can a marking plate be replaced?
Not by us and not by you. A design-type marking is issued against a specific container by the approval holder. A container whose marking is lost has lost it permanently — which is why we are insistent about protecting them.
06Who keeps the test records?
We keep ours and you get yours. Records travel with the container and are reissued on request, because the inspector who eventually asks for them will ask you, not us.
07Can testing be combined with a wash run?
Yes, and it is the sensible way to do it. Testing added to a wash run costs three to five days and one movement instead of two, so units leave your site once rather than twice.
Next step

Photograph one plate. Send it to us.

Design type and date are all we need to tell you what testing is due across the fleet and what it will cost.

Get a quote